Medtronic Resolute Integrity Stent different sizes

REF 10101 Disponible bajo pedido Precio bajo consulta

Medtronic Resolute Integrity Stent different sizes. Device: Zotarolimus-eluting coronary stent (DES); Stent material: Cobalt alloy (MP35N), continuous sinusoid design; Strut thickness: 91 µm (0.0036″); Drug / dose: Zotarolimus, ~1.6 µg/mm²; Polymer: BioLinx durable polymer over Parylene C. Wholesale supply by Med Technologies — request a…

Device
Zotarolimus-eluting coronary stent (DES)
Stent material
Cobalt alloy (MP35N), continuous sinusoid design
Strut thickness
91 µm (0.0036″)
Drug / dose
Zotarolimus, ~1.6 µg/mm²
Polymer
BioLinx durable polymer over Parylene C
Todas las especificaciones ↓
  • Nuevo, embalaje original
  • Lote y caducidad trazables
  • Documentos CE / MDR
  • Envíos a 4 continentes

Especificaciones

Fabricante
Medtronic
Referencia
10101
Device
Zotarolimus-eluting coronary stent (DES)
Stent material
Cobalt alloy (MP35N), continuous sinusoid design
Strut thickness
91 µm (0.0036″)
Drug / dose
Zotarolimus, ~1.6 µg/mm²
Polymer
BioLinx durable polymer over Parylene C
Nominal pressure
9 atm
Rated burst pressure
16 atm
Guide catheter
5F (ID ≥ 0.056″)
Guidewire
0.014″
Delivery system
Rapid exchange MicroTrac, 140 cm
Categoría
Coronary Stent
Estado
Nuevo, embalaje original

Según la documentación del fabricante. Consulte siempre las instrucciones de uso que acompañan al producto.

Descripción

Resolute Integrity is Medtronic’s zotarolimus-eluting stent built from a single continuous sinusoid of cobalt alloy (MP35N) wire, giving uniform flexibility and conformability; the BioLinx polymer releases ~1.6 µg/mm² zotarolimus over 180 days. Indicated for lesions up to 35 mm in vessels of 2.25–4.2 mm.

Reference 10101:nominal pressure 9 atm, rated burst pressure 16 atm, 91 µm struts, 5F guide compatible, 0.014″ guidewire, MicroTrac rapid-exchange delivery system 140 cm.

Available to order from Med Technologies — new, in original manufacturer packaging, CE-marked, with lot traceability. Contact us for pricing, stock and compatible sizes.

Specifications

ManufacturerMedtronic
Reference10101
DeviceZotarolimus-eluting coronary stent (DES)
Stent materialCobalt alloy (MP35N), continuous sinusoid design
Strut thickness91 µm (0.0036″)
Drug / doseZotarolimus, ~1.6 µg/mm²
PolymerBioLinx durable polymer over Parylene C
Nominal pressure9 atm
Rated burst pressure16 atm
Guide catheter5F (ID ≥ 0.056″)
Guidewire0.014″
Delivery systemRapid exchange MicroTrac, 140 cm
CategoryCoronary Stent
ConditionNew, original manufacturer packaging
CertificationCE marked
AvailabilityAvailable to order – request a quote

Need this reference or a compatible size? Med Technologies supplies hospitals and distributors worldwide. Request a quote for pricing, stock and lead time.

Pedido y documentación

  1. 01Elija la cantidad y añada el producto a su lista de presupuesto.
  2. 02Confirmamos precio, plazo de entrega y caducidad.
  3. 03Envío desde Bucarest con información de lote y caducidad.
¿Hay otras medidas o variantes?

Normalmente, sí. Indique las medidas que necesita en su solicitud y las cotizamos juntas.

¿Qué vida útil tendrá el producto?

Las fechas de caducidad se confirman por lote en el presupuesto, antes de pedir.

¿Pueden facilitar el certificado CE?

Sí: los certificados CE / MDR y las declaraciones de conformidad se entregan con su presupuesto.

Productos relacionados

Todo Coronary Stent →