Terumo Accuforce NC PTCA Balloon 3.5 x 8 mm

RÉF DC-RM3508HSW Disponible à la commande Prix sur demande

Terumo Accuforce NC PTCA Balloon 3.5 x 8 mm. Device: Non-compliant PTCA balloon catheter; Balloon diameter: 3.5 mm; Balloon length: 8 mm; Balloon construction: Triple-layer: elastomer inner/outer, polyamide middle layer; Nominal pressure: 12 atm. Wholesale supply by Med Technologies — request a quote.

Device
Non-compliant PTCA balloon catheter
Balloon diameter
3.5 mm
Balloon length
8 mm
Balloon construction
Triple-layer: elastomer inner/outer, polyamide middle layer
Nominal pressure
12 atm
Toutes les spécifications ↓
  • Neuf, emballage d’origine
  • Lot et péremption traçables
  • Documents CE / MDR
  • Expédition sur 4 continents

Spécifications

Fabricant
Terumo
Référence
DC-RM3508HSW
Device
Non-compliant PTCA balloon catheter
Balloon diameter
3.5 mm
Balloon length
8 mm
Balloon construction
Triple-layer: elastomer inner/outer, polyamide middle layer
Nominal pressure
12 atm
Rated burst pressure
up to 22 atm
Entry profile
0.43 mm
Usable length
145 cm
Shaft
Proximal 1.9F / distal 2.6F
Guidewire
0.014″
Catégorie
Balloon Catheter
État
Neuf, emballage d’origine

Selon la documentation du fabricant. Reportez-vous toujours à la notice d’utilisation fournie avec le dispositif.

Description

Accuforce is Terumo’s non-compliant PTCA balloon for high-pressure post-dilatation of stents and dilatation of resistant, calcified lesions. A triple-layer balloon (soft elastomer inner and outer layers over a polyamide core) gives a rated burst pressure of up to 22 atm with minimal diameter growth, so the balloon stays at the intended size during stent optimisation; the flexible 0.43 mm tip, thin short markers and hydrophilic shaft improve re-crossing of deployed stents.

Reference DC-RM3508HSW: 3.5 mm × 8 mm, nominal pressure 12 atm, 145 cm usable length, 1.9F/2.6F shaft, 0.014″ guidewire, 5F guide compatible (kissing balloon in 6F).

Available to order from Med Technologies — new, in original manufacturer packaging, CE-marked, with lot traceability. Contact us for pricing, stock and compatible sizes.

Specifications

ManufacturerTerumo
ReferenceDC-RM3508HSW
DeviceNon-compliant PTCA balloon catheter
Balloon diameter3.5 mm
Balloon length8 mm
Balloon constructionTriple-layer: elastomer inner/outer, polyamide middle layer
Nominal pressure12 atm
Rated burst pressureup to 22 atm
Entry profile0.43 mm
Usable length145 cm
ShaftProximal 1.9F / distal 2.6F
Guidewire0.014″
CategoryBalloon Catheter
ConditionNew, original manufacturer packaging
CertificationCE marked
AvailabilityAvailable to order – request a quote

Need this reference or a compatible size? Med Technologies supplies hospitals and distributors worldwide. Request a quote for pricing, stock and lead time.

Commande et documents

  1. 01Choisissez la quantité et ajoutez le produit à votre liste de devis.
  2. 02Nous confirmons prix, délai et dates de péremption.
  3. 03Expédié de Bucarest avec informations de lot et de péremption.
D’autres tailles ou variantes sont-elles disponibles ?

En général, oui. Indiquez les tailles souhaitées dans votre demande, nous les chiffrons ensemble.

Quelle durée de validité vais-je recevoir ?

Les dates de péremption sont confirmées par lot dans votre devis, avant commande.

Pouvez-vous fournir le certificat CE ?

Oui – certificats CE / MDR et déclarations de conformité sont fournis avec votre devis.

Produits associés

Tout Balloon Catheter →