Aesculap YASARGIL Titanium Aneurysm Clip FT807T – mini permanent, 4.7 mm blade

RÉF FT807T Disponible à la commande Prix sur demande

Aesculap YASARGIL Titanium Aneurysm Clip FT807T – mini permanent, 4.7 mm blade. Device: YASARGIL titanium aneurysm clip; Clip type: Mini (violet spring coding); Use: Permanent; Blade length: 4.7 mm; Max opening: 4.0 mm. Wholesale supply by Med Technologies — request a quote.

Device
YASARGIL titanium aneurysm clip
Clip type
Mini (violet spring coding)
Use
Permanent
Blade length
4.7 mm
Max opening
4.0 mm
Toutes les spécifications ↓
  • Neuf, emballage d’origine
  • Lot et péremption traçables
  • Documents CE / MDR
  • Expédition sur 4 continents

Spécifications

Fabricant
Aesculap
Référence
FT807T
Device
YASARGIL titanium aneurysm clip
Clip type
Mini (violet spring coding)
Use
Permanent
Blade length
4.7 mm
Max opening
4.0 mm
Closing force
110 g
Material
Titanium alloy, non-ferromagnetic
MRI
Tested up to 3 Tesla; minor CT/MRI artefact
Applier
Matching YASARGIL titanium clip applier
Catégorie
Microsurgery Instruments
État
Neuf, emballage d’origine

Selon la documentation du fabricant. Reportez-vous toujours à la notice d’utilisation fournie avec le dispositif.

Description

Aesculap YASARGIL titanium aneurysm clips are the reference clips for intracranial aneurysm surgery: a flat-spring design with precisely controlled closing force, in standard (blue coding, up to 200 g) and mini (violet, up to 110 g) sizes, straight, curved, bayonet, angled and fenestrated shapes. Permanent clips are implanted; temporary clips are used for proximal control. Titanium is non-ferromagnetic and tested to 3 Tesla with minimal imaging artefact.

Reference FT807T: mini permanent clip, blade length 4.7 mm, maximum opening 4.0 mm, closing force 110 g. Applied with the matching YASARGIL titanium applier; reusable, autoclavable.

Available to order from Med Technologies — new, in original manufacturer packaging, CE-marked, with lot traceability. Contact us for pricing, stock and compatible sizes.

Specifications

ManufacturerAesculap (B. Braun)
ReferenceFT807T
DeviceYASARGIL titanium aneurysm clip
Clip typeMini (violet spring coding)
UsePermanent
Blade length4.7 mm
Max opening4.0 mm
Closing force110 g
MaterialTitanium alloy, non-ferromagnetic
MRITested up to 3 Tesla; minor CT/MRI artefact
ApplierMatching YASARGIL titanium clip applier
CategoryMicrosurgery Instruments
ConditionNew, original manufacturer packaging
CertificationCE marked
AvailabilityAvailable to order – request a quote

Need this reference or a compatible size? Med Technologies supplies hospitals and distributors worldwide. Request a quote for pricing, stock and lead time.

Commande et documents

  1. 01Choisissez la quantité et ajoutez le produit à votre liste de devis.
  2. 02Nous confirmons prix, délai et dates de péremption.
  3. 03Expédié de Bucarest avec informations de lot et de péremption.
D’autres tailles ou variantes sont-elles disponibles ?

En général, oui. Indiquez les tailles souhaitées dans votre demande, nous les chiffrons ensemble.

Quelle durée de validité vais-je recevoir ?

Les dates de péremption sont confirmées par lot dans votre devis, avant commande.

Pouvez-vous fournir le certificat CE ?

Oui – certificats CE / MDR et déclarations de conformité sont fournis avec votre devis.