Medtronic Resolute Integrity DES 2.5 x 26 mm. Device: Zotarolimus-eluting coronary stent (DES); Stent diameter: 2.5 mm; Stent length: 26 mm; Stent material: Cobalt alloy (MP35N), continuous sinusoid design; Strut thickness: 91 µm (0.0036″). Wholesale supply by Med Technologies — request a quote.

Device
Zotarolimus-eluting coronary stent (DES)
Stent diameter
2.5 mm
Stent length
26 mm
Stent material
Cobalt alloy (MP35N), continuous sinusoid design
Strut thickness
91 µm (0.0036″)
Toutes les spécifications ↓
  • Neuf, emballage d’origine
  • Lot et péremption traçables
  • Documents CE / MDR
  • Expédition sur 4 continents

Spécifications

Fabricant
Medtronic
Référence
RSINT25026X
Device
Zotarolimus-eluting coronary stent (DES)
Stent diameter
2.5 mm
Stent length
26 mm
Stent material
Cobalt alloy (MP35N), continuous sinusoid design
Strut thickness
91 µm (0.0036″)
Drug / dose
Zotarolimus, ~1.6 µg/mm²
Polymer
BioLinx durable polymer over Parylene C
Nominal pressure
9 atm
Rated burst pressure
16 atm
Guide catheter
5F (ID ≥ 0.056″)
Catégorie
Coronary Stent
État
Neuf, emballage d’origine

Selon la documentation du fabricant. Reportez-vous toujours à la notice d’utilisation fournie avec le dispositif.

Description

Resolute Integrity is Medtronic’s zotarolimus-eluting stent built from a single continuous sinusoid of cobalt alloy (MP35N) wire, giving uniform flexibility and conformability; the BioLinx polymer releases ~1.6 µg/mm² zotarolimus over 180 days. Indicated for lesions up to 35 mm in vessels of 2.25–4.2 mm.

Reference RSINT25026X: 2.5 mm × 26 mm, nominal pressure 9 atm, rated burst pressure 16 atm, 91 µm struts, 5F guide compatible, 0.014″ guidewire, MicroTrac rapid-exchange delivery system 140 cm.

Available to order from Med Technologies — new, in original manufacturer packaging, CE-marked, with lot traceability. Contact us for pricing, stock and compatible sizes.

Specifications

ManufacturerMedtronic
ReferenceRSINT25026X
DeviceZotarolimus-eluting coronary stent (DES)
Stent diameter2.5 mm
Stent length26 mm
Stent materialCobalt alloy (MP35N), continuous sinusoid design
Strut thickness91 µm (0.0036″)
Drug / doseZotarolimus, ~1.6 µg/mm²
PolymerBioLinx durable polymer over Parylene C
Nominal pressure9 atm
Rated burst pressure16 atm
Guide catheter5F (ID ≥ 0.056″)
CategoryCoronary Stent
ConditionNew, original manufacturer packaging
CertificationCE marked
AvailabilityAvailable to order – request a quote

Need this reference or a compatible size? Med Technologies supplies hospitals and distributors worldwide. Request a quote for pricing, stock and lead time.

Commande et documents

  1. 01Choisissez la quantité et ajoutez le produit à votre liste de devis.
  2. 02Nous confirmons prix, délai et dates de péremption.
  3. 03Expédié de Bucarest avec informations de lot et de péremption.
D’autres tailles ou variantes sont-elles disponibles ?

En général, oui. Indiquez les tailles souhaitées dans votre demande, nous les chiffrons ensemble.

Quelle durée de validité vais-je recevoir ?

Les dates de péremption sont confirmées par lot dans votre devis, avant commande.

Pouvez-vous fournir le certificat CE ?

Oui – certificats CE / MDR et déclarations de conformité sont fournis avec votre devis.

Produits associés

Tout Coronary Stent →