Boston Scientific Promus Elite DES 3.5 x 20 mm
Boston Scientific Promus Elite DES 3.5 x 20 mm. Device: Everolimus-eluting coronary stent (DES); Stent diameter: 3.5 mm; Stent length: 20 mm; Stent material: Platinum chromium (PtCr) alloy; Strut thickness: 81 µm (0.0032″). Wholesale supply by Med Technologies — request a quote.
- Device
- Everolimus-eluting coronary stent (DES)
- Stent diameter
- 3.5 mm
- Stent length
- 20 mm
- Stent material
- Platinum chromium (PtCr) alloy
- Strut thickness
- 81 µm (0.0032″)
- Yeni, orijinal ambalaj
- Lot ve son kullanma izlenebilir
- CE / MDR belgeleri
- 4 kıtaya gönderim
Teknik özellikler
- Üretici
- Boston Scientific
- Referans
- H7493939920350
- Device
- Everolimus-eluting coronary stent (DES)
- Stent diameter
- 3.5 mm
- Stent length
- 20 mm
- Stent material
- Platinum chromium (PtCr) alloy
- Strut thickness
- 81 µm (0.0032″)
- Drug / dose
- Everolimus, 100 µg/cm²
- Polymer
- PVDF-HFP durable fluoropolymer
- Nominal pressure
- 11 atm
- Rated burst pressure
- 16 atm
- Guide catheter
- 5F (ID ≥ 0.056″)
- Kategori
- Coronary Stent
- Durum
- Yeni, orijinal ambalaj
Üretici belgelerine göre. Daima cihazla birlikte verilen kullanım talimatına başvurun.
Açıklama
Promus Elite is Boston Scientific’s everolimus-eluting coronary stent on the platinum-chromium platform: 81 µm (0.0032″) struts, a conformal PVDF-HFP fluoropolymer coating releasing 100 µg/cm² everolimus over 120 days, and high radiopacity and radial strength from the PtCr alloy. Indicated for de-novo and in-stent restenotic lesions in native coronary arteries 2.25–4.0 mm, lesion length ≤ 34 mm.
This reference (H7493939920350) is the 3.5 mm × 20 mm size: nominal pressure 11 atm, rated burst pressure 16 atm, 5F guide compatible (ID ≥ 0.056″), 0.014″ guidewire, rapid-exchange delivery system with 144 cm effective length.
Available to order from Med Technologies — new, in original manufacturer packaging, CE-marked, with lot traceability. Contact us for pricing, stock and compatible sizes.
Specifications
| Manufacturer | Boston Scientific |
|---|---|
| Reference | H7493939920350 |
| Device | Everolimus-eluting coronary stent (DES) |
| Stent diameter | 3.5 mm |
| Stent length | 20 mm |
| Stent material | Platinum chromium (PtCr) alloy |
| Strut thickness | 81 µm (0.0032″) |
| Drug / dose | Everolimus, 100 µg/cm² |
| Polymer | PVDF-HFP durable fluoropolymer |
| Nominal pressure | 11 atm |
| Rated burst pressure | 16 atm |
| Guide catheter | 5F (ID ≥ 0.056″) |
| Category | Coronary Stent |
| Condition | New, original manufacturer packaging |
| Certification | CE marked |
| Availability | Available to order – request a quote |
Need this reference or a compatible size? Med Technologies supplies hospitals and distributors worldwide. Request a quote for pricing, stock and lead time.
Sipariş ve belgeler
- 01Miktarı seçin ve ürünü teklif listenize ekleyin.
- 02Fiyat, teslim süresi ve son kullanma tarihlerini teyit ederiz.
- 03Lot ve son kullanma bilgileriyle Bükreş’ten gönderilir.
Başka ölçü veya varyantlar var mı?
Genellikle evet. Talebinizde ihtiyacınız olan ölçüleri yazın, birlikte fiyatlandıralım.
Ürünün raf ömrü ne olacak?
Son kullanma tarihleri sipariş öncesinde teklifte lot bazında teyit edilir.
CE sertifikasını sağlayabilir misiniz?
Evet – CE / MDR sertifikaları ve uygunluk beyanları teklifinizle birlikte sağlanır.