Aesculap YASARGIL Titanium Aneurysm Clip FT248T – standard temporary, 7.0 mm blade
Aesculap YASARGIL Titanium Aneurysm Clip FT248T – standard temporary, 7.0 mm blade. Device: YASARGIL titanium aneurysm clip; Clip type: Standard (blue spring coding); Use: Temporary; Blade length: 7.0 mm; Max opening: 7.9 mm. Wholesale supply by Med Technologies — request a quote.
- Device
- YASARGIL titanium aneurysm clip
- Clip type
- Standard (blue spring coding)
- Use
- Temporary
- Blade length
- 7.0 mm
- Max opening
- 7.9 mm
- 全新,原厂包装
- 批号与有效期可追溯
- CE / MDR 文件
- 发货至 4 大洲
技术参数
- 制造商
- Aesculap
- 参考编号
- FT248T
- Device
- YASARGIL titanium aneurysm clip
- Clip type
- Standard (blue spring coding)
- Use
- Temporary
- Blade length
- 7.0 mm
- Max opening
- 7.9 mm
- Closing force
- 90 g
- Material
- Titanium alloy, non-ferromagnetic
- MRI
- Tested up to 3 Tesla; minor CT/MRI artefact
- Applier
- Matching YASARGIL titanium clip applier
- 分类
- Microsurgery Instruments
- 状态
- 全新,原厂包装
依据制造商文件。请始终参照器械随附的使用说明书。
产品说明
Aesculap YASARGIL titanium aneurysm clips are the reference clips for intracranial aneurysm surgery: a flat-spring design with precisely controlled closing force, in standard (blue coding, up to 200 g) and mini (violet, up to 110 g) sizes, straight, curved, bayonet, angled and fenestrated shapes. Permanent clips are implanted; temporary clips are used for proximal control. Titanium is non-ferromagnetic and tested to 3 Tesla with minimal imaging artefact.
Reference FT248T: standard temporary clip, blade length 7.0 mm, maximum opening 7.9 mm, closing force 90 g. Applied with the matching YASARGIL titanium applier; reusable, autoclavable.
Available to order from Med Technologies — new, in original manufacturer packaging, CE-marked, with lot traceability. Contact us for pricing, stock and compatible sizes.
Specifications
| Manufacturer | Aesculap (B. Braun) |
|---|---|
| Reference | FT248T |
| Device | YASARGIL titanium aneurysm clip |
| Clip type | Standard (blue spring coding) |
| Use | Temporary |
| Blade length | 7.0 mm |
| Max opening | 7.9 mm |
| Closing force | 90 g |
| Material | Titanium alloy, non-ferromagnetic |
| MRI | Tested up to 3 Tesla; minor CT/MRI artefact |
| Applier | Matching YASARGIL titanium clip applier |
| Category | Microsurgery Instruments |
| Condition | New, original manufacturer packaging |
| Certification | CE marked |
| Availability | Available to order – request a quote |
Need this reference or a compatible size? Med Technologies supplies hospitals and distributors worldwide. Request a quote for pricing, stock and lead time.