Stent Resolute Onyx, 3.0/15

REF RONYX30015X 可订购 价格请询价

Stent Resolute Onyx, 3.0/15. Device: Zotarolimus-eluting coronary stent (DES), Onyx platform; Stent material: Cobalt alloy shell with platinum-iridium core (CoreWire), continuous sinusoid; Strut thickness: 81 µm (0.0032″); Drug / dose: Zotarolimus, ~1.6 µg/mm²; Polymer: BioLinx durable polymer over Parylene C. Wholesale supply by Med Technologies…

Device
Zotarolimus-eluting coronary stent (DES), Onyx platform
Stent material
Cobalt alloy shell with platinum-iridium core (CoreWire), continuous sinusoid
Strut thickness
81 µm (0.0032″)
Drug / dose
Zotarolimus, ~1.6 µg/mm²
Polymer
BioLinx durable polymer over Parylene C
全部技术参数 ↓
  • 全新,原厂包装
  • 批号与有效期可追溯
  • CE / MDR 文件
  • 发货至 4 大洲

技术参数

制造商
Medtronic
参考编号
RONYX30015X
Device
Zotarolimus-eluting coronary stent (DES), Onyx platform
Stent material
Cobalt alloy shell with platinum-iridium core (CoreWire), continuous sinusoid
Strut thickness
81 µm (0.0032″)
Drug / dose
Zotarolimus, ~1.6 µg/mm²
Polymer
BioLinx durable polymer over Parylene C
Nominal pressure
12 atm
Rated burst pressure
18 atm
Max post-dilatation diameter (MSID)
mm
Guide catheter
5F (ID ≥ 0.056″)
Guidewire
0.014″
分类
Coronary Stent
状态
全新,原厂包装

依据制造商文件。请始终参照器械随附的使用说明书。

产品说明

Resolute Onyx is built on Medtronic’s Onyx platform: a single continuous sinusoid of cobalt-alloy wire with a platinum-iridium core (CoreWire technology) for radiopacity at thin strut thickness, coated with the BioLinx durable polymer eluting ~1.6 µg/mm² zotarolimus over about 180 days. The Onyx platform carries the one-month DAPT indication for high-bleeding-risk patients (Onyx ONE) and spans 2.0–5.0 mm.

Reference RONYX30015X:strut thickness 81 µm (0.0032″), nominal pressure 12 atm, rated burst pressure 18 atm, maximum post-dilatation diameter mm, 5F (ID ≥ 0.056″) guide compatible, 0.014″ guidewire, rapid-exchange delivery system 140 cm.

Available to order from Med Technologies — new, in original manufacturer packaging, CE-marked, with lot traceability. Contact us for pricing, stock and compatible sizes.

Specifications

ManufacturerMedtronic
ReferenceRONYX30015X
DeviceZotarolimus-eluting coronary stent (DES), Onyx platform
Stent materialCobalt alloy shell with platinum-iridium core (CoreWire), continuous sinusoid
Strut thickness81 µm (0.0032″)
Drug / doseZotarolimus, ~1.6 µg/mm²
PolymerBioLinx durable polymer over Parylene C
Nominal pressure12 atm
Rated burst pressure18 atm
Max post-dilatation diameter (MSID)mm
Guide catheter5F (ID ≥ 0.056″)
Guidewire0.014″
CategoryCoronary Stent
ConditionNew, original manufacturer packaging
CertificationCE marked
AvailabilityAvailable to order – request a quote

Need this reference or a compatible size? Med Technologies supplies hospitals and distributors worldwide. Request a quote for pricing, stock and lead time.

订购与文件

  1. 01选择数量并将产品加入询价清单。
  2. 02我们确认价格、交货期和有效期。
  3. 03从布加勒斯特发货,附批号和有效期信息。
是否有其他规格或型号?

通常有。请在询价中写明所需规格,我们将一并报价。

产品有效期还剩多久?

有效期按批号在报价中确认,下单前即可知晓。

能提供 CE 证书吗?

可以——CE / MDR 证书和符合性声明随报价一同提供。