Aesculap YASARGIL Titanium Aneurysm Clip FT710T – mini permanent, 5.0 mm blade

REF FT710T Dostępny na zamówienie Cena na zapytanie

Aesculap YASARGIL Titanium Aneurysm Clip FT710T – mini permanent, 5.0 mm blade. Device: YASARGIL titanium aneurysm clip; Clip type: Mini (violet spring coding); Use: Permanent; Blade length: 5.0 mm; Max opening: 4.0 mm. Wholesale supply by Med Technologies — request a quote.

Device
YASARGIL titanium aneurysm clip
Clip type
Mini (violet spring coding)
Use
Permanent
Blade length
5.0 mm
Max opening
4.0 mm
Pełna specyfikacja ↓
  • Nowy, oryginalne opakowanie
  • Seria i ważność identyfikowalne
  • Dokumenty CE / MDR
  • Wysyłka na 4 kontynenty

Specyfikacja

Producent
Aesculap
Numer referencyjny
FT710T
Device
YASARGIL titanium aneurysm clip
Clip type
Mini (violet spring coding)
Use
Permanent
Blade length
5.0 mm
Max opening
4.0 mm
Closing force
110 g
Material
Titanium alloy, non-ferromagnetic
MRI
Tested up to 3 Tesla; minor CT/MRI artefact
Applier
Matching YASARGIL titanium clip applier
Kategoria
Microsurgery Instruments
Stan
Nowy, oryginalne opakowanie

Według dokumentacji producenta. Zawsze należy stosować się do instrukcji użycia dołączonej do wyrobu.

Opis

Aesculap YASARGIL titanium aneurysm clips are the reference clips for intracranial aneurysm surgery: a flat-spring design with precisely controlled closing force, in standard (blue coding, up to 200 g) and mini (violet, up to 110 g) sizes, straight, curved, bayonet, angled and fenestrated shapes. Permanent clips are implanted; temporary clips are used for proximal control. Titanium is non-ferromagnetic and tested to 3 Tesla with minimal imaging artefact.

Reference FT710T: mini permanent clip, blade length 5.0 mm, maximum opening 4.0 mm, closing force 110 g. Applied with the matching YASARGIL titanium applier; reusable, autoclavable.

Available to order from Med Technologies — new, in original manufacturer packaging, CE-marked, with lot traceability. Contact us for pricing, stock and compatible sizes.

Specifications

ManufacturerAesculap (B. Braun)
ReferenceFT710T
DeviceYASARGIL titanium aneurysm clip
Clip typeMini (violet spring coding)
UsePermanent
Blade length5.0 mm
Max opening4.0 mm
Closing force110 g
MaterialTitanium alloy, non-ferromagnetic
MRITested up to 3 Tesla; minor CT/MRI artefact
ApplierMatching YASARGIL titanium clip applier
CategoryMicrosurgery Instruments
ConditionNew, original manufacturer packaging
CertificationCE marked
AvailabilityAvailable to order – request a quote

Need this reference or a compatible size? Med Technologies supplies hospitals and distributors worldwide. Request a quote for pricing, stock and lead time.

Zamówienie i dokumenty

  1. 01Wybierz ilość i dodaj produkt do listy ofertowej.
  2. 02Potwierdzamy cenę, termin dostawy i daty ważności.
  3. 03Wysyłka z Bukaresztu z informacją o serii i dacie ważności.
Czy dostępne są inne rozmiary lub warianty?

Zwykle tak. Podaj potrzebne rozmiary w zapytaniu, a wycenimy je razem.

Jaki okres ważności otrzymam?

Daty ważności potwierdzamy dla każdej serii w ofercie, przed zamówieniem.

Czy możecie dostarczyć certyfikat CE?

Tak – certyfikaty CE / MDR i deklaracje zgodności są dostępne wraz z ofertą.