Aesculap YASARGIL Titanium Aneurysm Clip FT710T – mini permanent, 5.0 mm blade
Aesculap YASARGIL Titanium Aneurysm Clip FT710T – mini permanent, 5.0 mm blade. Device: YASARGIL titanium aneurysm clip; Clip type: Mini (violet spring coding); Use: Permanent; Blade length: 5.0 mm; Max opening: 4.0 mm. Wholesale supply by Med Technologies — request a quote.
- Device
- YASARGIL titanium aneurysm clip
- Clip type
- Mini (violet spring coding)
- Use
- Permanent
- Blade length
- 5.0 mm
- Max opening
- 4.0 mm
- Yeni, orijinal ambalaj
- Lot ve son kullanma izlenebilir
- CE / MDR belgeleri
- 4 kıtaya gönderim
Teknik özellikler
- Üretici
- Aesculap
- Referans
- FT710T
- Device
- YASARGIL titanium aneurysm clip
- Clip type
- Mini (violet spring coding)
- Use
- Permanent
- Blade length
- 5.0 mm
- Max opening
- 4.0 mm
- Closing force
- 110 g
- Material
- Titanium alloy, non-ferromagnetic
- MRI
- Tested up to 3 Tesla; minor CT/MRI artefact
- Applier
- Matching YASARGIL titanium clip applier
- Kategori
- Microsurgery Instruments
- Durum
- Yeni, orijinal ambalaj
Üretici belgelerine göre. Daima cihazla birlikte verilen kullanım talimatına başvurun.
Açıklama
Aesculap YASARGIL titanium aneurysm clips are the reference clips for intracranial aneurysm surgery: a flat-spring design with precisely controlled closing force, in standard (blue coding, up to 200 g) and mini (violet, up to 110 g) sizes, straight, curved, bayonet, angled and fenestrated shapes. Permanent clips are implanted; temporary clips are used for proximal control. Titanium is non-ferromagnetic and tested to 3 Tesla with minimal imaging artefact.
Reference FT710T: mini permanent clip, blade length 5.0 mm, maximum opening 4.0 mm, closing force 110 g. Applied with the matching YASARGIL titanium applier; reusable, autoclavable.
Available to order from Med Technologies — new, in original manufacturer packaging, CE-marked, with lot traceability. Contact us for pricing, stock and compatible sizes.
Specifications
| Manufacturer | Aesculap (B. Braun) |
|---|---|
| Reference | FT710T |
| Device | YASARGIL titanium aneurysm clip |
| Clip type | Mini (violet spring coding) |
| Use | Permanent |
| Blade length | 5.0 mm |
| Max opening | 4.0 mm |
| Closing force | 110 g |
| Material | Titanium alloy, non-ferromagnetic |
| MRI | Tested up to 3 Tesla; minor CT/MRI artefact |
| Applier | Matching YASARGIL titanium clip applier |
| Category | Microsurgery Instruments |
| Condition | New, original manufacturer packaging |
| Certification | CE marked |
| Availability | Available to order – request a quote |
Need this reference or a compatible size? Med Technologies supplies hospitals and distributors worldwide. Request a quote for pricing, stock and lead time.
Sipariş ve belgeler
- 01Miktarı seçin ve ürünü teklif listenize ekleyin.
- 02Fiyat, teslim süresi ve son kullanma tarihlerini teyit ederiz.
- 03Lot ve son kullanma bilgileriyle Bükreş’ten gönderilir.
Başka ölçü veya varyantlar var mı?
Genellikle evet. Talebinizde ihtiyacınız olan ölçüleri yazın, birlikte fiyatlandıralım.
Ürünün raf ömrü ne olacak?
Son kullanma tarihleri sipariş öncesinde teklifte lot bazında teyit edilir.
CE sertifikasını sağlayabilir misiniz?
Evet – CE / MDR sertifikaları ve uygunluk beyanları teklifinizle birlikte sağlanır.